Request a Quote for 5050213-2 by Miscellaneous
At Part 3sixty, we have Circuit Breaker components listed as NSN part number 5050213-2 by Miscellaneous along with a wide range of other parts that are readily available from a reliable manufacturer. In addition, we are the only independent distributors with the No China Sourcing pledge. Due to this, we are more vigilant in sourcing and inspecting our products, especially when it comes to the quality standards of our offerings. As a result, we can deliver premium quality 5050213-2 NSN parts in a timely manner, making us one of the leading online distributors of aviation and electronic parts.
Take advantage of our website’s search engine if you require specific parts such as fasteners, bearings, or any other part to support your aircraft. If you did not find your particular requirement that you need, you can also submit an instant RFQ, and one of our team members will contact you either through phone or email in less than 15 minutes. We are here to help our customers secure the parts that they need to effectively carry out their operations. Get in contact with a representative of ours at your earliest convenience, and they would be more than happy to assist you however necessary. At Parts 3sixty, we are more than just a dependable distributor of 5050213-2 NSN parts; we are your strategic sourcing partner in an ever changing market.
Specifications
| Part Number | 5050213-2 |
| Description | Circuit Breaker |
| Manufacturer | Miscellaneous |
| NSN | 5925-01-200-7812(5925012007812) |
| Item Name | Circuit Breaker |
| CAGE Code | 57958 |
| NIIN | 01-200-7812(012007812) |
| FSC Code | 5925 Circuit Breakers |
| FSG Code | 59 Electrical and Electronic Equipment Components |
| Part Type | Circuit Breaker |
| Sub Part Type | — |
| INC Code | 00136 |
| NCB Code | 01 |
| Country | USA |
| Specification | — |
Description
Request a Quote
Get pricing for 5050213-2
Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/customer-terms-and-conditions/. All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without CAGE code 6RE77 is void.
NSN Information for Part Number 5050213-2 with NSN 5925-01-200-7812, 5925012007812
Characteristics Data of NSN 5925-01-200-7812, 5925012007812
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
| ABTD | MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 3.544 INCHES NOMINAL" |
| ADAT | BODY WIDTH | 4.128 INCHES NOMINAL" |
| ADTV | CASE MATERIAL | PLASTIC" |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.546 INCHES NOMINAL" |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.032 INCHES NOMINAL" |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL" |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.032 INCHES NOMINAL" |
| AJEC | BOSS HEIGHT | 0.218 INCHES NOMINAL" |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.609 INCHES NOMINAL" |
| AKPX | POLE QUANTITY | 4" |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT" |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE AND 8 SLOT" |
| CMLP | THREAD QUANTITY PER INCH | 32" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.0 AMPERES AC FOURTH LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC FIRST LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC SECOND LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC THIRD LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC FOURTH LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SECOND LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION" |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS" |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
| CPRQ | RESET METHOD | MANUAL" |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE" |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SHUNT TRIP FOURTH LOCATION" |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.530 MINIMUM AT 200 PCT FOURTH LOCATION AND 1.500 MAXIMUM AT 200 PCT FOURTH LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT FIRST LOCATION AND 105.000 MAXIMUM AT 200 PCT FIRST LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT SECOND LOCATION AND 105.000 MAXIMUM AT 200 PCT SECOND LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT THIRD LOCATION AND 105.000 MAXIMUM AT 200 PCT THIRD LOCATION" |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF" |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
| THSD | THREAD SERIES DESIGNATOR | UNC" |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 THREADED STUD" |
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
| ABTD | MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 3.544 INCHES NOMINAL" |
| ADAT | BODY WIDTH | 4.128 INCHES NOMINAL" |
| ADTV | CASE MATERIAL | PLASTIC" |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.546 INCHES NOMINAL" |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.032 INCHES NOMINAL" |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL" |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.032 INCHES NOMINAL" |
| AJEC | BOSS HEIGHT | 0.218 INCHES NOMINAL" |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.609 INCHES NOMINAL" |
| AKPX | POLE QUANTITY | 4" |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT" |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE AND 8 SLOT" |
| CMLP | THREAD QUANTITY PER INCH | 32" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 0.0 AMPERES AC FOURTH LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC FIRST LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC SECOND LOCATION" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC THIRD LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC FOURTH LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SECOND LOCATION" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION" |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS" |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
| CPRQ | RESET METHOD | MANUAL" |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE" |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SHUNT TRIP FOURTH LOCATION" |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.530 MINIMUM AT 200 PCT FOURTH LOCATION AND 1.500 MAXIMUM AT 200 PCT FOURTH LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT FIRST LOCATION AND 105.000 MAXIMUM AT 200 PCT FIRST LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT SECOND LOCATION AND 105.000 MAXIMUM AT 200 PCT SECOND LOCATION" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 40.000 MINIMUM AT 200 PCT THIRD LOCATION AND 105.000 MAXIMUM AT 200 PCT THIRD LOCATION" |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF" |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
| THSD | THREAD SERIES DESIGNATOR | UNC" |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 THREADED STUD" |